Mini-Project 2: Sensor Calibration Simulator
Duration: 3-4 hours Module: Module 2 - The Digital Twin Prerequisites: Labs 1-3 completed, understanding of simulated sensors and ROS 2 topics
Overview
Build a simulation environment for testing and calibrating multiple robot sensors. This project integrates sensor configuration, data pipeline concepts, and validation techniques from Module 2, creating a tool that can be used to tune sensor parameters before deployment.
Objectives
Create a sensor calibration system with:
- Multiple configurable sensors (camera, LiDAR, IMU)
- Calibration targets and reference objects
- Data collection and analysis tools
- Sensor accuracy validation scripts
- ROS 2 integration for real-time calibration
System Architecture
┌─────────────────────────────────────────────────────────────────┐
│ Sensor Calibration Environment │
│ │
│ ┌─────────────────┐ ┌─────────────────┐ │
│ │ Calibration │ │ Reference │ │
│ │ Target Board │ │ Objects │ │
│ │ (Checkerboard) │ │ (Known sizes) │ │
│ └─────────────────┘ └─────────────────┘ │
│ │
│ ┌─────────────────────────────┐ │
│ │ Robot with Sensors │ │
│ │ ┌───────┐ ┌───────┐ ┌───┐ │ │
│ │ │Camera │ │ LiDAR │ │IMU│ │ │
│ │ └───────┘ └───────┘ └───┘ │ │
│ └─────────────────────────────┘ │
│ │ │
│ ▼ │
│ ┌─────────────────────────────┐ │
│ │ Calibration Node (ROS 2) │ │
│ │ - Collect sensor data │ │
│ │ - Compare to ground truth │ │
│ │ - Calculate error metrics │ │
│ │ - Generate calibration │ │
│ └─────────────────────────────┘ │
└─────────────────────────────────────────────────────────────────┘
Requirements
1. Calibration Environment
Create a calibration world (calibration_room.sdf) with:
Calibration Targets:
- Checkerboard pattern for camera calibration (1m x 1m)
- Distance markers at known positions (1m, 2m, 3m, 5m)
- Reference cube with known dimensions (0.5m x 0.5m x 0.5m)
Environment Features:
- Clean, well-lit indoor environment
- Flat floor with distance grid markings
- Neutral colored walls for clear sensor readings
- Multiple target positions for comprehensive testing
2. Sensor Configuration
Configure sensors with adjustable parameters:
# sensor_calibration_config.yaml
camera:
resolution: [640, 480]
fov: 1.047 # 60 degrees
update_rate: 30
noise:
type: gaussian
stddev: 0.02
lidar:
samples: 360
range_min: 0.1
range_max: 10.0
update_rate: 10
noise:
type: gaussian
stddev: 0.01
imu:
update_rate: 100
noise:
angular_velocity:
stddev: 0.001
linear_acceleration:
stddev: 0.01
3. Calibration Node
Create sensor_calibrator.py ROS 2 node:
# Node should:
# 1. Subscribe to all sensor topics
# 2. Collect calibration data samples
# 3. Compare measurements to known ground truth
# 4. Calculate error metrics (RMSE, mean error, std dev)
# 5. Generate calibration report
4. Validation Tests
Create tests to validate sensor accuracy:
Camera Tests:
- Detect checkerboard corners
- Verify FOV coverage
- Measure color accuracy
LiDAR Tests:
- Measure distance to known targets
- Verify scan coverage (360°)
- Calculate range accuracy at different distances
IMU Tests:
- Verify gravity vector (9.81 m/s²)
- Test orientation stability
- Measure drift over time
Getting Started
Setup Workspace
cd ~/ros2_ws/src
ros2 pkg create --build-type ament_python sensor_calibration \
--dependencies rclpy sensor_msgs geometry_msgs cv_bridge numpy
Starter Files
Use the starter code in starter/ directory:
worlds/calibration_room_template.sdf- Environment templateconfig/sensor_config_template.yaml- Sensor configurationsensor_calibration/calibrator_node.py- Calibration node templatesensor_calibration/validation_tests.py- Test script template
Running the Calibration
# Build the package
colcon build --packages-select sensor_calibration
# Launch calibration environment
ros2 launch sensor_calibration calibration.launch.py
# Run calibration node
ros2 run sensor_calibration calibrator_node
# Run validation tests
ros2 run sensor_calibration validation_tests
Evaluation Criteria
| Criterion | Points |
|---|---|
| Calibration environment with targets | 15 |
| Camera calibration working | 20 |
| LiDAR accuracy validation | 20 |
| IMU gravity/orientation test | 15 |
| Error metrics calculated correctly | 15 |
| Calibration report generated | 10 |
| Clean code and documentation | 5 |
| Total | 100 |
Extensions (Bonus)
- Interactive Calibration: GUI for adjusting sensor parameters in real-time
- Multi-sensor Fusion: Cross-validate sensors against each other
- Automated Calibration: Implement automatic parameter tuning
- Export Calibration: Save calibration data in standard formats (YAML, JSON)
- Temperature Simulation: Model sensor drift with simulated temperature changes
- Noise Characterization: Implement Allan variance analysis for IMU
Hints
- Use OpenCV for checkerboard detection (
cv2.findChessboardCorners) - Store ground truth positions in a configuration file
- Collect multiple samples and average for better accuracy
- Use
numpyfor statistical calculations - Log data with timestamps for time-series analysis
- Consider sensor synchronization for multi-sensor comparison
Solution
See solution/ directory for complete implementation including:
worlds/calibration_room.sdf- Complete calibration environmentconfig/sensor_config.yaml- Tuned sensor configurationsensor_calibration/calibrator_node.py- Working calibration nodesensor_calibration/validation_tests.py- Complete test suite
Calibration Report Format
Your calibration node should generate a report like:
=== Sensor Calibration Report ===
Date: 2024-01-15 14:30:00
Duration: 60 seconds
Samples collected: 600
--- Camera Calibration ---
Resolution: 640x480
Checkerboard detected: YES
Reprojection error: 0.23 pixels
FOV measured: 59.8° (expected: 60°)
--- LiDAR Calibration ---
Range accuracy (1m target): 0.012m RMSE
Range accuracy (3m target): 0.018m RMSE
Range accuracy (5m target): 0.025m RMSE
Angular resolution: 1.0°
Coverage: 360°
--- IMU Calibration ---
Gravity magnitude: 9.807 m/s² (expected: 9.81)
Orientation drift: 0.02°/min
Accelerometer noise: 0.008 m/s² std
Gyroscope noise: 0.0008 rad/s std
--- Overall Status ---
Camera: PASS
LiDAR: PASS
IMU: PASS
Reflection Questions
- Why is sensor calibration important before deploying a robot in the real world?
- How do simulated sensor noise models compare to real sensor noise characteristics?
- What additional calibration would you need for a multi-camera system?
- How would you calibrate sensor timing/synchronization?
- What is the sim-to-real gap for sensor calibration, and how can it be minimized?